TITANEX. H07RN-F Tough Rubber. Heavy Duty Outdoor Events Mains Cable
Multibuy discounts calculated at checkout
Industrial flexible cable, insulation and outer sheath in elastomer. Oil resistant, flame retardant according to IEC/EN 60332-1-2 standard.
Industrial flexible cable, insulation and outer sheath in elastomer. Oil resistant, flame retardant according to IEC/EN 60332-1-2 standard.
TITANEX® flexible cable is intended for installations with moving equipment, electric appliances and for building sites. The cable may be rated 0,6/1 kV where the installation has built-in protection and for motors in lifting appliances - machine tools - etc.
This cable can be used in refrigerating installations.
This cable can be installed in open air or be buried but with extra mechanical protection.
Max continuous operating conductor temperature in normal use :
- +60°C ( in every case of mobile installation)
- +85°C ( fixed protected installation )
- +200°C ( in short circuit )
Permissible current rating is measured for an ambient temperature of 30°C and a maximum operating and conductor temperature of 85°C.
For other temperature please refer to correction factors.
Technical Info
Construction characteristics
- Lead free Yes
- Sheath colour Black
- Conductor material Bare copper
- Outer sheath Special cross-linked elastomer
- Insulation Special cross-linked elastomer
Mechanical characteristics
- Mechanical resistance to impacts Very good
- Cable flexibility Flexible
Usage characteristics
- Chemical resistance Accidental
- Water proof Good
- RoHS conform Yes
- Operating temperature, range -25 .. 55 °C
- Short-circuit max. conductor temperature 200 °C
- Oil resistance Yes
- Max. conductor temperature in service 85 °C
Specific characteristics
1x25mm
- Number of cores: 1
- Cross sectional area: 25mm
- Notional MAX Current rating: 141amps (Table 4E1A, in free air or tray, touching)
- Weight: 369 grams / per meter
1x35mm
- Number of cores: 1
- Cross sectional area: 35mm
- Notional MAX Current rating: 176amps (Table 4E1A, in free air or tray, touching)
- Weight: 482 grams / per meter
1x50mm
- Number of cores: 1
- Cross sectional area: 50mm
- Notional MAX Current rating: 216amps (Table 4E1A, in free air or tray, touching)
- Weight: 662 grams / per meter
1x70mm
- Number of cores: 1
- Cross sectional area: 70mm
- Notional MAX Current rating: 279amps (Table 4E1A, in free air or tray, touching)
- Weight: 895 grams / per meter
1x95mm
- Number of cores: 1
- Cross sectional area: 95mm
- Notional MAX Current rating: 342amps (Table 4E1A, in free air or tray, touching)
- Weight: 1144 grams / per meter (1.14kg)
3x1mm
- Number of cores: 3
- Cross sectional area: 1mm
- Notional MAX Current rating: 10amps (Table 4F3A)
- Weight: 117 grams / per meter
3x1.5mm
- Number of cores: 3
- Cross sectional area: 1.5mm
- Notional MAX Current rating: 16amps (Table 4F3A)
- Weight: 134 grams / per meter
3x2.5mm
- Number of cores: 3
- Cross sectional area: 2.5mm
- Notional MAX Current rating: 25amps (Table 4F3A)
- Weight: 195 grams / per meter
3x4mm
- Number of cores: 3
- Cross sectional area: 4mm
- Notional MAX Current rating: 32amps (Table 4F3A)
- Weight: 260 grams / per meter
3x6mm
- Number of cores: 3
- Cross sectional area: 6mm
- Notional MAX Current rating: 39amps (Table 4F1A)
- Weight: 346 grams / per meter
3x10mm
- Number of cores: 3
- Cross sectional area: 10mm
- Notional MAX Current rating: 51amps (Table 4F1A)
- Weight: 663 grams / per meter
3x16mm
- Number of cores: 3
- Cross sectional area: 16mm
- Notional MAX Current rating: 73amps (Table 4F1A)
- Weight: 924 grams / per meter
3x25mm
- Number of cores: 3
- Cross sectional area: 25mm
- Notional MAX Current rating: 97amps (Table 4F1A)
- Weight: 1345 grams / per meter (1.3kg)
5x2.5mm
- Number of cores: 5
- Cross sectional area: 2.5mm
- Notional MAX Current rating: 20amps (Table 4F3A)
- Weight: 297 grams / per meter
5x4mm
- Number of cores: 5
- Cross sectional area: 4mm
- Notional MAX Current rating: 26amps (Table 4F1A)
- Weight: 453 grams / per meter
5x6mm
- Number of cores: 5
- Cross sectional area: 6mm
- Notional MAX Current rating: 34amps (Table 4F1A)
- Weight: 557 grams / per meter
5x10mm
- Number of cores: 5
- Cross sectional area: 10mm
- Notional MAX Current rating: 47amps (Table 4F1A)
- Weight: 1001 grams / per meter (1.01kg)
5x16mm
- Number of cores: 5
- Cross sectional area: 16mm
- Notional MAX Current rating: 63amps (Table 4F1A)
- Weight: 1430 grams / per meter (1.43kg)
5x25mm
- Number of cores: 5
- Cross sectional area: 25mm
- Notional MAX Current rating: 83amps (Table 4F1A)
- Weight: 2096 grams / per meter (2.10kg)
5x35mm
- Number of cores: 5
- Cross sectional area: 35mm
- Notional MAX Current rating: 102amps (Table 4F1A)
- Weight: Not specified
5x50mm
- Number of cores: 5
- Cross sectional area: 50mm
- Notional MAX Current rating: 124amps (Table 4F1A)
- Weight: Not specified
5x70mm
- Number of cores: 5
- Cross sectional area: 70mm
- Notional MAX Current rating: 158amps (Table 4F1A)
- Weight: Not specified
5x95mm
- Number of cores: 5
- Cross sectional area: 95mm
- Notional MAX Current rating: 192amps (Table 4F1A)
- Weight: Not specified